Indian Journal of Respiratory Care

IJRC Email      Register      Login

VOLUME 2 , ISSUE 2 ( July-December, 2013 ) > List of Articles

Original Article

Comparison of two techniques of airway anaesthesia for awake fibreoptic nasotracheal intubation in patients with anticipated difficult airway

B Rakesh Rai, U Kailasnath Shenoy

Keywords : Airway, anaesthesia, difficult airway, fibreoptic intubation

Citation Information : Rai BR, Shenoy UK. Comparison of two techniques of airway anaesthesia for awake fibreoptic nasotracheal intubation in patients with anticipated difficult airway. Indian J Respir Care 2013; 2 (2):313-319.

DOI: 10.5005/jp-journals-11010-02210

License: NA

Published Online: 05-12-2022

Copyright Statement:  NA


Abstract

Introduction: The success of awake fibreoptic assisted intubation often depends on the adequacy of anaesthesia of the airway and patient comfort for the procedure. Aim: To compare the standard technique (nerve block) of airway anaesthesia with simple aspiration of lignocaine. Methods: Thirty patients in whom difficult airway was anticipated were randomly allocated into either Group A (Aspiration) and Group B (Nerve block). In Group A, 0.2 mL/kg of 1.5% lignocaine was trickled on to the dorsum of the tongue while the patient was encouraged to breathe through the mouth. In Group B, superior laryngeal nerve block and intratracheal injection of lignocaine was used. Fibreoptic bronchoscopy was then carried out by a consultant anaesthesiologist, who was blinded to the local anaesthetic technique used. The patient responses to instrumentation of pharynx, glottis and trachea, and tolerance of the endotracheal tube were noted. Results: Two cases were excluded from the study because of bleeding resulting in subsequent loss of visualisation of glottis through bronchoscope. There was no statistical or clinical difference in the patient responses between the two groups (P > 0.05) due to fibreoptic bronchoscope in the pharynx, larynx and endotracheal tube in the trachea or with regard to the use of rescue medications. Conclusions: Aspiration of 1.5% lignocaine (0.2 mL/kg) provides clinically comparable conditions for intubation as the nerve block technique for awake fibreoptic nasotracheal intubation in patients with anticipated difficult airway.


HTML PDF Share
  1. Caplan RA, Benumof JL, Berry FA. Practice guidelines for management of the difficult airway. Anesthesiology 1993; 78:597-602.
  2. Crosby ET, Cooper RM, Douglas MI. The unanticipated difficult airway with recommendations for management. Can J Anaesth 1998; 45:757-76.
  3. Kahrilas PJ, Lin S, Logemann JA, Ergun GA, Facchini F. Deglutitive tongue action: volume accoimmodation and bolus preparation. Gastroenterology 1993; 104:152-62.
  4. Chung DC, Mainland PA, Kong AS. Anesthesia of airway by aspiration. Anesth Analg 2009; 21: 246.
  5. Sidhu VS, Whitehead EM, Ainsworth, Smith M, Calder J. A technique of awake fibreoptic intubation. Anaesthesia 1993; 48:910-3.
  6. Reasoner DK, Warner DS, Todd MM, Hunt SW, Kirchner J. A comparison of anaesthetic technique for awake intubation in neurosurgical patients. J Neurosurg Anesthesiolol 1995; 7:94-9.
  7. Graham DR, John GH, Clague J, Nisar M, Earis JE. Comparison of three different methods used to achieve local anaesthesia for fibreoptic bronchoscopy. Chest 1992; 102: 704-7.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.